Design of a control with multiple inputs multiple outputs by decoupling
datacite.rights | http://purl.org/coar/access_right/c_abf2 | spa |
dc.contributor.author | González, J.R. | |
dc.contributor.author | Correa, G. | |
dc.contributor.author | Montoya, O.D. | |
dc.date.accessioned | 2023-07-21T16:22:50Z | |
dc.date.available | 2023-07-21T16:22:50Z | |
dc.date.issued | 2021 | |
dc.date.submitted | 2023 | |
dc.description.abstract | In industry, most processes can be modeled by a system of equations that can be monovariable or multivariable. In our case, we will present a multivariable system more adjusted to real cases and on which a control system is available. This article presents a decoupling control method for two inputs two outputs through a centralized multivariable controller using a decoupling network and a diagonal controller, this technical advantage allows reduction in computing time. It shows the methodology by which a multivariate system can be represented as the composition of different coupled systems in this way that the control of the variables involved in it can be done separately, facilitating the control system, this implies a modification in the outputs to be affected. In the same way, the two-inlet with 2-outlet distillation system was also studied. © Published under licence by IOP Publishing Ltd. | spa |
dc.format.extent | 8 páginas | |
dc.format.mimetype | application/pdf | spa |
dc.identifier.citation | González, J. R., Correa, G., & Montoya, O. D. (2021, July). Design of a control with multiple inputs multiple outputs by decoupling. In Journal of Physics: Conference Series (Vol. 1981, No. 1, p. 012002). IOP Publishing. | spa |
dc.identifier.doi | 10.1088/1742-6596/1981/1/012002 | |
dc.identifier.instname | Universidad Tecnológica de Bolívar | spa |
dc.identifier.reponame | Repositorio Universidad Tecnológica de Bolívar | spa |
dc.identifier.uri | https://hdl.handle.net/20.500.12585/12331 | |
dc.language.iso | eng | spa |
dc.publisher.place | Cartagena de Indias | spa |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | spa |
dc.rights.cc | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.source | Journal of Physics: Conference Series | spa |
dc.subject.armarc | LEMB | |
dc.subject.keywords | Controller; | spa |
dc.subject.keywords | Internal Model Control; | spa |
dc.subject.keywords | Decoupling Control | spa |
dc.title | Design of a control with multiple inputs multiple outputs by decoupling | spa |
dc.type.driver | info:eu-repo/semantics/article | spa |
dc.type.hasversion | info:eu-repo/semantics/draft | spa |
dc.type.spa | http://purl.org/coar/resource_type/c_6501 | spa |
dcterms.bibliographicCitation | Duarte, M., Sepúlveda, F., Castillo, A., Contreras, A., Lazcano, V., Giménez, P., Castelli, L. A comparative experimental study of five multivariable control strategies applied to a grinding plant (1999) Powder Technology, 104 (1), pp. 1-28. Cited 31 times. doi: 10.1016/S0032-5910(98)00210-1 | spa |
dcterms.bibliographicCitation | Garrido, J (2012) Diseño de Sistemas de Control Multivariable por Desacoplo con Controladores PID. Cited 3 times. (Spain: Universidad de Córdoba) | spa |
dcterms.bibliographicCitation | Bristol, E.H. On a new measure of interaction for multivariable process control (1966) IEEE Transactions on Automatic Control, 11 (1), pp. 133-134. Cited 1310 times. doi: 10.1109/TAC.1966.1098266 | spa |
dcterms.bibliographicCitation | Cai, W.-J., Ni, W., He, M.-J., Ni, C.-Y. Normalized decoupling - a new approach for MIMO process control system design (2008) Industrial and Engineering Chemistry Research, 47 (19), pp. 7347-7356. Cited 86 times. doi: 10.1021/ie8006165 | spa |
dcterms.bibliographicCitation | Quintero, C, Oñate, J, Jimenez, J (2018) Control Automático Aplicado (Colombia: Universidad del Norte) | spa |
dcterms.bibliographicCitation | Bristol, E.H. On a new measure of interaction for multivariable process control (1966) IEEE Transactions on Automatic Control, 11 (1), pp. 133-134. Cited 1310 times. doi: 10.1109/TAC.1966.1098266 | spa |
dcterms.bibliographicCitation | Calderón Osorio, J C Control de Procesos Multivariables Mediante un Sistema de Control Distribuido Modificado. Cited 3 times. (Colombia: Universidad Nacional de Colombia) | spa |
dcterms.bibliographicCitation | Chen, J., He, Z.-F., Qi, X. A new control method for MIMO first order time delay non-square systems (2011) Journal of Process Control, 21 (4), pp. 538-546. Cited 85 times. doi: 10.1016/j.jprocont.2011.01.007 | spa |
dcterms.bibliographicCitation | Astrom, K, Hagglund, T (1995) PID Controllers: Theory, Design and Tuning. Cited 4590 times. (North Carolina: Instrument Society of America) | spa |
dcterms.bibliographicCitation | Llata, J R, Oria, J P, Sarabia, E G, Arce, J, Robles, A (2006) Control Predictivo de Tanques Acoplados (Spain: Universidad de Cantabria) | spa |
dcterms.bibliographicCitation | Zhang, W., Wang, Y., Liu, Y., Zhang, W. Multivariable disturbance observer-based H 2 analytical decoupling control design for multivariable systems (2016) International Journal of Systems Science, 47 (1), pp. 179-193. Cited 10 times. http://www.tandf.co.uk/journals/titles/00207721.asp doi: 10.1080/00207721.2015.1036479 | spa |
dcterms.bibliographicCitation | He, G., Li, J., Cui, P. Decoupling control design for the module suspension control system in maglev train (2015) Mathematical Problems in Engineering, 2015, art. no. 865650. Cited 14 times. http://www.hindawi.com/journals/mpe/contents.html doi: 10.1155/2015/865650 | spa |
oaire.resourcetype | http://purl.org/coar/resource_type/c_6501 | spa |
oaire.version | http://purl.org/coar/version/c_b1a7d7d4d402bcce | spa |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Garrido-Arévalo_2020_J._Phys.__Conf._Ser._1448_012009.pdf
- Size:
- 827.37 KB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 3.11 KB
- Format:
- Item-specific license agreed upon to submission
- Description: