Publicación: Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system
| datacite.rights | http://purl.org/coar/access_right/c_16ec | |
| dc.contributor.author | Marrugo Hernández, Andrés Guillermo | |
| dc.contributor.author | Martínez Santos, Juan Carlos | |
| dc.creator | Diaz Parada R.A. | |
| dc.date.accessioned | 2020-03-26T16:32:50Z | |
| dc.date.available | 2020-03-26T16:32:50Z | |
| dc.date.issued | 2014 | |
| dc.description.abstract | This article describes the implementation and use of a two-accelerometer system to measure the angle formed between lower joints of weightlifters during the execution of the technical gesture. Being aware of movement between joints will allow identifying bad moves and prevent injuries in athletes. Likewise, it will help in turn to rehabilitation for people with problems in the movement of their joints. This design is based on open platforms both hardware and software. The preliminary result shows that we can connect a two-accelerometer system with an error in the measure of the angle no greater than 1.3% (0.795% on average). © 2014 IEEE. | eng |
| dc.description.sponsorship | Universidad Tecnologica de Bolivar | |
| dc.format.medium | Recurso electrónico | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.citation | 2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings | |
| dc.identifier.doi | 10.1109/CIIMA.2014.6983443 | |
| dc.identifier.instname | Universidad Tecnológica de Bolívar | |
| dc.identifier.isbn | 9781479979325 | |
| dc.identifier.orcid | 56682876700 | |
| dc.identifier.orcid | 26325154200 | |
| dc.identifier.reponame | Repositorio UTB | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12585/9044 | |
| dc.language.iso | eng | |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
| dc.relation.conferencedate | 22 October 2014 through 24 October 2014 | |
| dc.rights.accessrights | info:eu-repo/semantics/restrictedAccess | |
| dc.rights.cc | Atribución-NoComercial 4.0 Internacional | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.source | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84930989293&doi=10.1109%2fCIIMA.2014.6983443&partnerID=40&md5=a4e736290f03b6e43df922fd4d025cd6 | |
| dc.source | Scopus2-s2.0-84930989293 | |
| dc.source.event | 2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 | |
| dc.subject.keywords | Mechatronics | |
| dc.subject.keywords | Hardware and software | |
| dc.subject.keywords | Open platforms | |
| dc.subject.keywords | Accelerometers | |
| dc.title | Study of the lower limp's angle during weightlifting exercises using an accelerometer-based system | |
| dc.type | Conferencia | |
| dc.type.driver | info:eu-repo/semantics/conferenceObject | |
| dc.type.hasversion | info:eu-repo/semantics/publishedVersion | |
| dcterms.bibliographicCitation | Instituto Distrital de Recreación y Deporte, , http://ider.gov.co/ | |
| dcterms.bibliographicCitation | Mayagoitia, R.E., Nene, A.V., Veltink, P.H., Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems (2002) Journal of Biomechanics, 35 (4), pp. 537-542 | |
| dcterms.bibliographicCitation | Cheng, P., Oelmann, B., Joint-angle measurement using accelerometers and gyroscopes?a survey (2010) Instrumentation and Measurement, IEEE Transactions on, 59 (2), pp. 404-414 | |
| dcterms.bibliographicCitation | Fry, B., Reas, C., (2014) Processing Library for Visual Arts and Design, , http://www.processing.org, Aug | |
| dcterms.bibliographicCitation | Xiao-Mao, G., Bao-Sheng, Z., Fan, Z., Yu-Jie, Y., Wei, Z., Xi, L., Optimal design model for crank-connecting rod mechanism of atype stirling engine (2011) Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference On. IEEE, pp. 519-522 | |
| dcterms.bibliographicCitation | Veltink, P.H., Franken, H.M., Detection of knee unlock during stance by accelerometry (1996) Rehabilitation Engineering, IEEE Transactions on, 4 (4), pp. 395-402 | |
| dcterms.bibliographicCitation | Dong, W., Chen, I., Lim, K., Goh, Y., (2007) Measuring Uniaxial Joint Angles with A Minimal Accelerometer Configuration, pp. 88-91 | |
| dcterms.bibliographicCitation | Dejnabadi, H., Jolles, B.M., Aminian, K., A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes (2005) Biomedical Engineering, IEEE Transactions on, 52 (8), pp. 1478-1484 | |
| dcterms.bibliographicCitation | (2008) Producto Punto, , http://www.geoan.com/analitica/vectores/productopunto.html | |
| dcterms.bibliographicCitation | (2014) ADXL35 Datasheet and Product Info, , http://www.analog.com/en/mems-sensors/memsinertial-sensors/adxl335/products/product.html, Aug | |
| dspace.entity.type | Publication | |
| oaire.resourceType | http://purl.org/coar/resource_type/c_c94f | |
| oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| relation.isAuthorOfPublication | 651b0410-2e8f-4894-87bc-d3d803c92eab | |
| relation.isAuthorOfPublication | 35de2f55-a620-47ac-97f2-9961adeac601 | |
| relation.isAuthorOfPublication.latestForDiscovery | 651b0410-2e8f-4894-87bc-d3d803c92eab |