Hybrid calibration method for improving 3D measurement accuracy of structured light systems
Ver/
Fecha
2020-08-21Autor(es)
Marrugo Hernández, Andrés Guillermo
Vargas, Raul
Zhang, Song
Romero, Lenny A.
Metadatos
Mostrar el registro completo del ítemResumen
In structured-light systems, the lens distortions of the camera and the projector reduce the measurement accuracy when calibrated as a standard stereo-vision system. The conventional compensation via distortion coefficients reduces the error, but still leaves a significant residual. Recently, we proposed a hybrid calibration procedure that leverages the standard calibration approach to improve measurement accuracy. This hybrid procedure consisted of building a pixel-wise phase-to-coordinate mapping based on adjusted 3D data obtained from the standard stereo-vision method. Here, we show experimentally that the measurement accuracy can be significantly improved, even using the linear pinhole model and linear mapping functions. We then move to consider the nonlinear model to improve the measurement accuracy further. Encouraging results show that this new calibration method increases the measurement accuracy without requiring elaborate calibration procedures or sophisticated ancillary equipment.
Citar como
Andres G. Marrugo, Raul Vargas, Song Zhang, and Lenny A. Romero "Hybrid calibration method for improving 3D measurement accuracy of structured light systems", Proc. SPIE 11490, Interferometry XX, 1149008 (21 August 2020); https://doi.org/10.1117/12.2567650Utilice esta dirección para citar:
https://hdl.handle.net/20.500.12585/9545Recurso Original
https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11490/1149008/Hybrid-calibration-method-for-improving-3D-measurement-accuracy-of-structured/10.1117/12.2567650.short?webSyncID=a28531ab-0d3a-6b03-c97c-009b6bcd746b&sessionGUID=80d8e8ab-eeae-d6ae-05c1-17aac5a91993Todo el contenido:
https://www.spiedigitallibrary.org/conference-proceedings-of-spie/11490/1149008/Hybrid-calibration-method-for-improving-3D-measurement-accuracy-of-structured/10.1117/12.2567650.short?webSyncID=a28531ab-0d3a-6b03-c97c-009b6bcd746b&sessionGUID=80d8e8ab-eeae-d6ae-05c1-17aac5a91993Colecciones
- Productos de investigación [1453]
Compatible para recolección con:
Archivos
Universidad Tecnológica de Bolívar - 2017 Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional. Resolución No 961 del 26 de octubre de 1970 a través de la cual la Gobernación de Bolívar otorga la Personería Jurídica a la Universidad Tecnológica de Bolívar.