Mostrar el registro sencillo del ítem

dc.contributor.editorMarrugo Hernández, Andrés Guillermo
dc.creatorMagre Colorado, Luz Alejandra
dc.creatorMartínez-Santos, Juan Carlos
dc.date.accessioned2020-03-26T16:32:50Z
dc.date.available2020-03-26T16:32:50Z
dc.date.issued2014
dc.identifier.citation2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014 - Conference Proceedings
dc.identifier.isbn9781479979325
dc.identifier.urihttps://hdl.handle.net/20.500.12585/9043
dc.description.abstractOlympic-style weightlifting, or weightlifting, is an athletic discipline that has as a goal lift the heaviest amount of weight attached a weight set. Weightlifting complements other athletic disciplines to increase power and improve performance. Weight training exercises are also an important part of physical rehabilitation from muscle, joint, tendons, and ligaments injuries. To determinate its efficiency, optimize it, prevent lesions, or help in the rehab process indirect and direct methods are commonly used. Direct methods use data from muscular signals to estimate force, torque, and kinematic variables whereas indirect methods like as close range photogrammetric get data directly from a video camera. In this paper, we present a non-invasive system to recover the positions and motion pathways of weight set during lifting moment. Active and passive tracking marks are used to leverage the detection of points of interest. Kinematic parameters were collected and analyzed using moving pictures analysis system implemented in Processing and using OpenCV (Open Source Computer Vision) framework. The preliminary results indicate that our close range photogrammetric method is able to measure kinematic variable in weightlifting during physical or rehab training as well as during competition. Our experiment shows the error in the position measure is less than 2.24% in average. © 2014 IEEE.eng
dc.description.sponsorshipUniversidad Tecnologica de Bolivar
dc.format.mediumRecurso electrónico
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.sourcehttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84930995211&doi=10.1109%2fCIIMA.2014.6983439&partnerID=40&md5=1ca4604e0c235318e22bfa8392d68912
dc.sourceScopus2-s2.0-84930995211
dc.titleUsing close range photogrammetric method to estimate kinetic variables in olympic-style weightlifting
dcterms.bibliographicCitationRogers, P., (2012) Weight Training in Rehabilitation Recover Quickly from Injury, , http://weighttraining.about.com/od/physicaltherapy/a/Weight-Training-In-Rehabilitation.htm, July
dcterms.bibliographicCitationBronzino, J., (2000) The Biomedical Engineering Handbook, , Springer
dcterms.bibliographicCitationJovanov, E., Milenkovic, A., Otto, C., De Groen, P.C., A wireless body area network of intelligent motion sensors for computer assisted physical rehabilitation (2005) Journal of NeuroEngineering and Rehabilitation, 2 (1), p. 6
dcterms.bibliographicCitationWang, L., Yang, G.-Z., Huang, J., Zhang, J., Yu, L., Nie, Z., Cumming, D.R.S., A wireless biomedical signal interface system-on-chip for body sensor networks (2010) Biomedical Circuits and Systems, IEEE Transactions on, 4 (2), pp. 112-117
dcterms.bibliographicCitationGarhammer, J., Takano, B., (1992) Training for Weightlifting, , T. E. of Sports Medicine, Ed. Oxford: Blackwell Scientific
dcterms.bibliographicCitationIsaka, T., Okada, J., Funato, K., Kinematic analysis of the barbell during the snatch movement of elite asian weight lifters (1996) Journal of Applied Biomechanics, 12, pp. 508-516
dcterms.bibliographicCitationCampillo, P., Hertogh, C., Micallef, J.P., Puntos críticos del tirón de arrancada en halterofilia (1999) Apunts Educación Física y Deportes, 55, pp. 28-34
dcterms.bibliographicCitationGourgoulis, V., Aggeloussis, N., Antoniou, P., Christoforidis, C., Mavromatis, G., Garas, A., Comparative 3-dimensional kinematic analysis of the snatch technique in elite male and female greek weightlifters (2002) Journal Strength Cond Res, 16, pp. 359-366
dcterms.bibliographicCitationCampos, J., Poletaev, P., Cuesta, A., Pablos, C., Tébar, J., Estudio del movimiento de arrancada en halterofilia durante ciclos de repeticiones de alta intensidad mediante analisis cinematicos (2010) Motricidad. European Journal of Human Movement, 12, pp. 37-51
dcterms.bibliographicCitation(2014) Face2face c8.0, , http://www.iball.co.in/Product/Face2Face-C8-0-Rev-3-0-/90
dcterms.bibliographicCitation(2014) Processing.org, , http://www.processing.org
dcterms.bibliographicCitation(2014) Rgb Color Model, , http://en.wikipedia.org/wiki/RGBcolormodel
dcterms.bibliographicCitationHarbili, E., Análisis cinemático y cinético por sexos del arranque en halterófilos de elite pertenecientes a la categoría de 69 kg (2012) PubliCE Standard
dcterms.bibliographicCitationVelloso, E., Bulling, A., Gellersen, H., Towards qualitative assessment of weight lifting exercises using body-worn sensors (2011) Proceedings of the 13th International Conference on Ubiquitous Computing. ACM, pp. 587-588
datacite.rightshttp://purl.org/coar/access_right/c_16ec
oaire.resourceTypehttp://purl.org/coar/resource_type/c_c94f
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dc.source.event2014 3rd International Congress of Engineering Mechatronics and Automation, CIIMA 2014
dc.type.driverinfo:eu-repo/semantics/conferenceObject
dc.type.hasversioninfo:eu-repo/semantics/publishedVersion
dc.identifier.doi10.1109/CIIMA.2014.6983439
dc.subject.keywordsComputer vision
dc.subject.keywordsKinematics
dc.subject.keywordsOpen systems
dc.subject.keywordsTracking (position)
dc.subject.keywordsVideo cameras
dc.subject.keywordsClose-range photogrammetric
dc.subject.keywordsImprove performance
dc.subject.keywordsIndirect methods
dc.subject.keywordsKinematic parameters
dc.subject.keywordsKinematic variables
dc.subject.keywordsKinetic variables
dc.subject.keywordsPhysical rehabilitation
dc.subject.keywordsPoints of interest
dc.subject.keywordsPhotogrammetry
dc.rights.accessrightsinfo:eu-repo/semantics/restrictedAccess
dc.rights.ccAtribución-NoComercial 4.0 Internacional
dc.identifier.instnameUniversidad Tecnológica de Bolívar
dc.identifier.reponameRepositorio UTB
dc.relation.conferencedate22 October 2014 through 24 October 2014
dc.type.spaConferencia
dc.identifier.orcid56682785300
dc.identifier.orcid26325154200


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by-nc-nd/4.0/
http://creativecommons.org/licenses/by-nc-nd/4.0/

Universidad Tecnológica de Bolívar - 2017 Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional. Resolución No 961 del 26 de octubre de 1970 a través de la cual la Gobernación de Bolívar otorga la Personería Jurídica a la Universidad Tecnológica de Bolívar.