Effectiveness of a visual noise warning system on noise levels in a surgical ICU: A quality improvement programme
dc.creator | Guisasola-Rabes M. | |
dc.creator | Solà-Enriquez B. | |
dc.creator | Vélez-Pereira A.M. | |
dc.creator | De Nadal M. | |
dc.date.accessioned | 2020-03-26T16:32:37Z | |
dc.date.available | 2020-03-26T16:32:37Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | European Journal of Anaesthesiology; Vol. 36, Núm. 11; pp. 857-862 | |
dc.identifier.issn | 02650215 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12585/8928 | |
dc.description.abstract | BACKGROUNDThe effects of noise are harmful to patients in the ICU environment, and the latter are particularly noisy places. High noise levels seem to be a factor in sleep disturbance, which can, in turn, result in increased morbidity.LOCAL PROBLEMHigh noise levels are a recognised problem in ICUs worldwide.OBJECTIVE(S)The goal was to estimate the effect of a visual noise-warning system on noise levels in a surgical ICU before and after its implementation.DESIGNA quality improvement initiative.SETTINGA 12-bedded surgical ICU in a tertiary care university hospital.PATIENTSA total of 148 adult nonintubated and nonsedated patients completed the study, during a 6-week period.INTERVENTIONNoise levels were continuously recorded using a Type II sound level meter for 6 weeks. The study was divided into three phases. The first 2 weeks, baseline noise levels were measured (phase I). In week 3 of the study, a visual noise warning system (SoundEar II) that changed colour depending on noise levels within the ICU was installed and implemented (phase II). The alarm system was set to light up green at levels below 55 dBA, orange at levels between 55 and 60 dBA and red at levels above 60 dBA. The device was switched off at the beginning of week 5 and the sound level meter continued recording noise levels for another 2 weeks (phase III).RESULTSMean night-time noise level was 55.98 dBA in the preintervention phase, 54.14 dB during the intervention, and 54.98 dBA in the postintervention phase. Mean noise level was reduced statistically significantly by 1.35 dBA, and there was a sustained reduction of 0.86 dBA from the baseline noise level 2 weeks after SoundEar II was switched off.CONCLUSIONVisual noise warning systems can be effective in achieving a reduction in noise levels in critical care units. © 2019 European Society of Anaesthesiology. All rights reserved. | eng |
dc.format.medium | Recurso electrónico | |
dc.format.mimetype | application/pdf | |
dc.language.iso | eng | |
dc.publisher | Lippincott Williams and Wilkins | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.source | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85072905029&doi=10.1097%2fEJA.0000000000001038&partnerID=40&md5=7f76e9b857553e35bcedcc852b921211 | |
dc.title | Effectiveness of a visual noise warning system on noise levels in a surgical ICU: A quality improvement programme | |
dcterms.bibliographicCitation | Litton, E., Carnegie, V., Elliott, R., The efficacy of earplugs as a sleep hygiene strategy for reducing delirium in the ICU: A systematic review and meta-analysis (2016) Crit Care Med, 44, pp. 992-999 | |
dcterms.bibliographicCitation | Grandner, M.A., Hale, L., Moore, M., Mortality associated with short sleep duration: The evidence, the possible mechanisms, and the future sleep duration and mortality: The evidence (2010) Sleep Med Rev, 14, pp. 191-203 | |
dcterms.bibliographicCitation | Gallicchio, L., Kalesan, B., Sleep duration and mortality: A systematic review and meta-analysis (2009) J Sleep Res, 18, pp. 148-158 | |
dcterms.bibliographicCitation | Darbyshire, J.L., Young, J.D., An investigation of sound levels on intensive care units with reference to the WHO guidelines (2013) Crit Care, 17, p. R187 | |
dcterms.bibliographicCitation | Berglund, B., Lindvall, T., Schwela, D.H., (1999) Guidelines for Community Noise-A Table of Contents, , WHO | |
dcterms.bibliographicCitation | Ryherd, E., West, J.E., Ilene, B.-V.K.P.W., (2008) Evaluating the Hospital Soundscape, , http://acousticstoday.org/wp-content/uploads/2017/07/Article_3of3_from_ATCODK_4_4.pdf, Acoust Today [Internet]. [Cited 2. July 2018] | |
dcterms.bibliographicCitation | Camargo, A.P., Caicedo, Y., Velez, P.A., Equivalent continuous noise level in a neonatal intensive care unit associated to burnout syndrome (2015) Enferm Intensiva, 26, pp. 92-100. , 1130-2399 | |
dcterms.bibliographicCitation | Meyer, T.J., Eveloff, S.E., Bauer, M.S., Adverse environmental conditions in the respiratory and medical ICU settings (1994) Chest, 105, pp. 1211-1216 | |
dcterms.bibliographicCitation | Freedman, N.S., Gazendam, J., Levan, L., Abnormal sleep/wake cycles and the effect of environmental noise on sleep disruption in the intensive care unit (2001) Am J Respir Crit Care Med, 163, pp. 451-457 | |
dcterms.bibliographicCitation | Xie, H., Kang, J., Mills, G.H., Clinical review: The impact of noise on patients' sleep and the effectiveness of noise reduction strategies in intensive care units (2009) Crit Care, 13, p. 208 | |
dcterms.bibliographicCitation | Wenham, T., Pittard, A., Intensive care unit environment (2009) Contin Educ Anaesth Crit Care Pain, 9, pp. 178-183 | |
dcterms.bibliographicCitation | Elbaz, M., L-Eger, D., Sauvet, F., Sound level intensity severely disrupts sleep in ventilated ICU patients throughout a 24-h period: A preliminary 24-h study of sleep stages and associated sound levels (2017) Ann Intensive Care, 7, pp. 1-9 | |
dcterms.bibliographicCitation | Horsten, S., Reinke, L., Absalom, A.R., Systematic review of the effects of intensive-care-unit noise on sleep of healthy subjects and the critically ill (2018) Br J Anaesth, 120, pp. 443-452 | |
dcterms.bibliographicCitation | Plummer, N.R., Herbert, A., Blundell, J.E., SoundEar noise warning devices cause a sustained reduction in ambient noise in adult critical care (2019) J Intensive Care Soc, 20, pp. 106-110 | |
dcterms.bibliographicCitation | Walder, B., Romand, J.A., Lançon, M., Effects of guidelines implementation in a surgical intensive care unit to control nighttime light and noise levels (2000) Crit Care Med, 28, pp. 2242-2247 | |
dcterms.bibliographicCitation | Hilton, B.A., Quantity and quality of patients' sleep and sleep-disturbing factors in a respiratory intensive care unit (1976) J Adv Nurs, 1, pp. 453-468 | |
dcterms.bibliographicCitation | Hilton, B.A., Noise in acute patient care areas (1985) Res Nurs Health, 8, pp. 283-291 | |
dcterms.bibliographicCitation | Richardson, A., Allsop, M., Coghill, E., Earplugs and eye masks: Do they improve critical care patients' sleep? (2007) Nurs Crit Care, 12, pp. 278-286 | |
dcterms.bibliographicCitation | Akansel, N., Kaymakçi, S., Effects of intensive care unit noise on patients: A study on coronary artery bypass graft surgery patients (2008) J Clin Nurs, 17, pp. 1581-1590 | |
dcterms.bibliographicCitation | Park, M., Kohlrausch, A., De Bruijn, W., Analysis of the soundscape in an intensive care unit based on the annotation of an audio recording (2014) J Acoust Soc Am, 135, pp. 1875-1886 | |
dcterms.bibliographicCitation | Van Rompaey, B., Elseviers, M.M., Van Drom, W., The effect of earplugs during the night on the onset of delirium and sleep perception: A randomized controlled trial in intensive care patients (2012) Crit Care, 16, p. R73 | |
dcterms.bibliographicCitation | Sandoval, C.P., Nonpharmacological interventions for sleep promotion in the intensive care unit (2017) Crit Care Nurse, 37, pp. 100-102 | |
dcterms.bibliographicCitation | Le Guen, M., Nicolas-Robin, A., Lebard, C., Earplugs and eye masks vs routine care prevent sleep impairment in postanaesthesia care unit: A randomized study (2014) Br J Anaesth, 112, pp. 89-95 | |
dcterms.bibliographicCitation | Hu, R.F., Jiang, X.Y., Hegadoren, K.M., Effects of earplugs and eye masks combined with relaxing music on sleep, melatonin and cortisol levels in ICU patients: A randomized controlled trial (2015) Crit Care, 19, p. 115 | |
dcterms.bibliographicCitation | Simons, K.S., Verweij, E., Lemmens, P.M.C., Noise in the intensive care unit and its influence on sleep quality: A multicenter observational study in Dutch intensive care units (2018) Crit Care, 22, p. 250 | |
dcterms.bibliographicCitation | Garrido, G.A.P., Camargo, C.Y., Velez-Pereira, A.M., Noise level in a neonatal intensive care unit in Santa Marta-Colombia (2017) Colomb Med, 48, pp. 120-125 | |
dcterms.bibliographicCitation | Fortes-Garrido, J., Velez-Pereira, A., G-Azquez, M., The characterization of noise levels in a neonatal intensive care unit and the implications for noise management (2014) J Environ Heal Sci Eng, 12, p. 104 | |
dcterms.bibliographicCitation | Gabor, J.Y., Cooper, A.B., Crombach, S.A., Contribution of the intensive care unit environment to sleep disruption in mechanically ventilated patients and healthy subjects (2003) Am J Respir Crit Care Med, 167, pp. 708-715 | |
dcterms.bibliographicCitation | Elliott, R., McKinley, S., Cistulli, P., Characterisation of sleep in intensive care using 24-h polysomnography: An observational study (2013) Crit Care, 17, p. R46 | |
dcterms.bibliographicCitation | Shipman, J.T., Wilson, J.D., Higgins, C., (2012) An Introduction to Physical Science, , Boston, MA: Brooks/Cole | |
datacite.rights | http://purl.org/coar/access_right/c_16ec | |
oaire.resourceType | http://purl.org/coar/resource_type/c_6501 | |
oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
dc.type.driver | info:eu-repo/semantics/article | |
dc.type.hasversion | info:eu-repo/semantics/publishedVersion | |
dc.identifier.doi | 10.1097/EJA.0000000000001038 | |
dc.subject.keywords | Adult | |
dc.subject.keywords | Article | |
dc.subject.keywords | Female | |
dc.subject.keywords | Human | |
dc.subject.keywords | Major clinical study | |
dc.subject.keywords | Male | |
dc.subject.keywords | Noise | |
dc.subject.keywords | Noise measurement | |
dc.subject.keywords | Recording | |
dc.subject.keywords | Sleep disorder | |
dc.subject.keywords | Sound intensity | |
dc.subject.keywords | Surgical intensive care unit | |
dc.subject.keywords | Total quality management | |
dc.subject.keywords | SC420 | |
dc.subject.keywords | SoundEar II | |
dc.rights.accessrights | info:eu-repo/semantics/restrictedAccess | |
dc.rights.cc | Atribución-NoComercial 4.0 Internacional | |
dc.identifier.instname | Universidad Tecnológica de Bolívar | |
dc.identifier.reponame | Repositorio UTB | |
dc.type.spa | Artículo | |
dc.identifier.orcid | 57192180702 | |
dc.identifier.orcid | 57211182435 | |
dc.identifier.orcid | 55817731200 | |
dc.identifier.orcid | 6602959140 |
Ficheros en el ítem
Ficheros | Tamaño | Formato | Ver |
---|---|---|---|
No hay ficheros asociados a este ítem. |
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Productos de investigación [1460]
Universidad Tecnológica de Bolívar - 2017 Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional. Resolución No 961 del 26 de octubre de 1970 a través de la cual la Gobernación de Bolívar otorga la Personería Jurídica a la Universidad Tecnológica de Bolívar.