Mostrar el registro sencillo del ítem

dc.contributor.authorRubiano-Labrador, Carolina
dc.contributor.authorBaena De Avila, Ludys
dc.contributor.authorDoria Posada, Dayana
dc.contributor.authorAcevedo-Barrios, Rosa
dc.date.accessioned2023-07-21T16:25:59Z
dc.date.available2023-07-21T16:25:59Z
dc.date.issued2022
dc.date.submitted2023
dc.identifier.citationRubiano-Labrador, C., De Avila, L. B., Doria Posada, D., & Acevedo-Barrios, R. (2022). Concentrations of Airborne Cultivable Fungi at a Higher Education Institution in Cartagena de Indias, Colombian Caribbean. Aerosol Science and Engineering, 6(4), 381-390.spa
dc.identifier.urihttps://hdl.handle.net/20.500.12585/12349
dc.description.abstractBioaerosols are as small particles suspended in air that contain several microorganisms (bacteria, fungi, and viruses). These particles are studied because of the possible impacts that they have on the health of humans and animals in open and closed spaces. In this study, the presence of airborne fungi presents in a Higher Education Institution (HEI) of the city of Cartagena de Indias, Colombian Caribbean was evaluated. Over 4 months (June–October 2018), 128 fungal samples were collected using a two-stage cascade impactor, and the fungi present in these samples were counted, characterized, and identified. Bioaerosol concentrations were correlated with meteorological data from the Rafael Núñez Airport meteorological station to establish the possible influence of these factors on the presence of bioaerosols. The results obtained showed an average concentration of fungal aerosols of 123.71 ± 17.97 UFC/m3, with the highest proportion occurring in the morning. The predominant genera were Aspergillus (60.8%), followed by Penicillium (24.5%) and Fusarium (9.3%). According to the correlations obtained from a multivariate analysis, the meteorological parameters did not influence the presence of microorganisms at the HEI studied; however, a possible influence of emission sources such as vegetation and industry is suggested. © 2022, The Author(s) under exclusive licence to Institute of Earth Environment, Chinese Academy Sciences.spa
dc.format.extent9 páginas
dc.format.mimetypeapplication/pdfspa
dc.language.isoengspa
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceAerosol Science and Engineering, 6(4spa
dc.titleConcentrations of Airborne Cultivable Fungi at a Higher Education Institution in Cartagena de Indias, Colombian Caribbeanspa
dcterms.bibliographicCitationAlmaguer, M., Aira, M.-J., Rodríguez-Rajo, F.J., Rojas, T.I. Temporal dynamics of airborne fungi in Havana (Cuba) during dry and rainy seasons: influence of meteorological parameters (2014) International journal of biometeorology, 58 (7), pp. 1459-1470. Cited 34 times. doi: 10.1007/s00484-013-0748-6spa
dcterms.bibliographicCitationAraujo, J., Rojas, Y., Yegres, F. Evaluación aeromicrobiológica en la costa del puerto de La Vela de Coro, patrimonio cultural de la humanidad (2013) Multiciencias, 13, pp. 355-362. Cited 4 times.spa
dcterms.bibliographicCitationBelizario, J.A., Lopes, L.G., Pires, R.H. Fungi in the indoor air of critical hospital areas: a review (2021) Aerobiologia, 37 (3), pp. 379-394. Cited 10 times. www.wkap.nl/journalhome.htm/0393-5965 doi: 10.1007/s10453-021-09706-7spa
dcterms.bibliographicCitationBrągoszewska, E., Biedroń, I., Kozielska, B., Pastuszka, J.S. Microbiological indoor air quality in an office building in Gliwice, Poland: analysis of the case study (2018) Air Quality, Atmosphere and Health, 11 (6), pp. 729-740. Cited 51 times. http://www.springer.com/environment/environmental+health+-+public+health/journal/11869 doi: 10.1007/s11869-018-0579-zspa
dcterms.bibliographicCitationCaicedo, L., Giusiano, G., Alvarez, M. Estudio de la micota ambiental de tres edificios de laboratorios de la Universidad del Valle, Colombia, y su relación con los síntomas de alergias respiratorias que manifiestan trabajadores (2015) Universidad Nacional Del Nordeste, p. 100.spa
dcterms.bibliographicCitationCamargo, Y.C., Dh, M., Velez-Pereira, A. (2011) Emisiones atmosféricas de origen biológico, Santa Marta, Colombia. Cited 4 times.spa
dcterms.bibliographicCitationCaraballo, L., Puerta, L., Fernández-Caldas, E., Lockey, R.F. (1998) Sensibilización a los alérgenos de ácaros y al asma aguda en un ambiente tropicalspa
dcterms.bibliographicCitation(2010) Clima Cartagena https://www.cioh.org.co/meteorologia/Climatologia/ResumenCartagena2.phpspa
dcterms.bibliographicCitationDedesko, S., Stephens, B., Gilbert, J.A., Siegel, J.A. Methods to assess human occupancy and occupant activity in hospital patient rooms (2015) Building and Environment, 90, pp. 136-145. Cited 46 times. http://www.elsevier.com/inca/publications/store/2/9/6/index.htt doi: 10.1016/j.buildenv.2015.03.029spa
dcterms.bibliographicCitationDouwes, J., Thorne, P., Pearce, N., Heederik, D. Bioaerosol health effects and exposure assessment: Progress and prospects (2003) Annals of Occupational Hygiene, 47 (3), pp. 187-200. Cited 1047 times. doi: 10.1093/annhyg/meg032spa
dcterms.bibliographicCitationDouwes, J., Eduard, W., Thorne, P.S. Bioaerosols (2016) International Encyclopedia of Public Health, pp. 210-218. Cited 2 times. http://www.sciencedirect.com/science/book/9780128037089 ISBN: 978-012803708-9; 978-012803678-5 doi: 10.1016/B978-0-12-803678-5.00032-1spa
dcterms.bibliographicCitationEgbuta, M.A., Mwanza, M., Babalola, O.O. Health risks associated with exposure to filamentous fungi (2017) International Journal of Environmental Research and Public Health, 14 (7), art. no. 719. Cited 67 times. http://www.mdpi.com/1660-4601/14/7/719/pdf doi: 10.3390/ijerph14070719spa
dcterms.bibliographicCitationEl-Morsy, E.-S.M. Preliminary survey of indoor and outdoor airborne microfungi at coastal buildings in Egypt (2006) Aerobiologia, 22 (3), pp. 197-210. Cited 31 times. doi: 10.1007/s10453-006-9032-0spa
dcterms.bibliographicCitationFaridi, S., Hassanvand, M.S., Naddafi, K., Yunesian, M., Nabizadeh, R., Sowlat, M.H., Kashani, H., (...), Alimohammadi, M. Indoor/outdoor relationships of bioaerosol concentrations in a retirement home and a school dormitory (2015) Environmental Science and Pollution Research, 22 (11), pp. 8190-8200. Cited 50 times. http://www.springerlink.com/content/0944-1344 doi: 10.1007/s11356-014-3944-yspa
dcterms.bibliographicCitationFayad, R.K., Al-Thani, R.F., Al-Naemi, F.A., Abu-Dieyeh, M.H. Diversity, concentration and dynamics of culturable fungal bioaerosols at doha, qatar (2021) International Journal of Environmental Research and Public Health, 18 (1), art. no. 182, pp. 1-21. Cited 4 times. https://www.mdpi.com/1660-4601/18/1/182/pdf doi: 10.3390/ijerph18010182spa
dcterms.bibliographicCitation(2013) Análisis de conectividad de bosque seco tropical en cuatro ventanas del Caribe Colombiano. In: FCDS (ed). Fundación para la Conservación y el Desarollo Sostenible, p 71spa
dcterms.bibliographicCitationFröhlich-Nowoisky, J., Kampf, C.J., Weber, B., Huffman, J.A., Pöhlker, C., Andreae, M.O., Lang-Yona, N., (...), Pöschl, U. Bioaerosols in the Earth system: Climate, health, and ecosystem interactions (2016) Atmospheric Research, 182, pp. 346-376. Cited 524 times. http://www.elsevier.com/inca/publications/store/5/0/3/3/2/3/index.htt doi: 10.1016/j.atmosres.2016.07.018spa
dcterms.bibliographicCitationGeorgiadou, S.P., Velegraki, A., Arabatzis, M., Neonakis, I., Chatzipanagiotou, S., Dalekos, G.N., Petinaki, E. Cluster of Fusarium verticillioides bloodstream infections among immunocompetent patients in an internal medicine department after reconstruction works in Larissa, Central Greece (2014) Journal of Hospital Infection, 86 (4), pp. 267-271. Cited 15 times. http://www.elsevier.com/inca/publications/store/6/2/3/0/5/2/index.htt doi: 10.1016/j.jhin.2014.01.011spa
dcterms.bibliographicCitationGilbert, Y., Duchaine, C. Bioaerosols in industrial environments: A review (Open Access) (2009) Canadian Journal of Civil Engineering, 36 (12), pp. 1873-1886. Cited 34 times. http://article.pubs.nrc-cnrc.gc.ca/RPAS/RPViewDoc?_handler_=HandleInitialGet&calyLang=eng&journal=cjce&volume=36&articleFile=l09-117.pdf doi: 10.1139/L09-117spa
dcterms.bibliographicCitationGołofit-Szymczak, M., Górny, R.L. Microbiological air quality in office buildings equipped with dventilation systems (2018) Indoor Air, 28 (6), pp. 792-805. Cited 33 times. http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0668 doi: 10.1111/ina.12495spa
dcterms.bibliographicCitationHeo, K.J., Kim, H.B., Lee, B.U. Concentration of environmental fungal and bacterial bioaerosols during the monsoon season (2014) Journal of Aerosol Science, 77, pp. 31-37. Cited 53 times. www.elsevier.com/locate/jaerosci doi: 10.1016/j.jaerosci.2014.07.001spa
dcterms.bibliographicCitationHosseini, N., Hajizadeh, Y., Nikaeen, M., Hatamzadeh, M. Spatiotemporal variation of ambient bioaerosols in a large and industrialized metropolis of Iran and their association with PM2.5 and meteorological factors (2021) Aerobiologia, 37 (1), pp. 105-117. Cited 5 times. www.wkap.nl/journalhome.htm/0393-5965 doi: 10.1007/s10453-020-09672-6spa
dcterms.bibliographicCitationHuang, C.-Y., Lee, C.-C., Li, F.-C., Ma, Y.-P., Su, H.-J.J. The seasonal distribution of bioaerosols in municipal landfill sites: A 3-yr study (2002) Atmospheric Environment, 36 (27), pp. 4385-4395. Cited 85 times. doi: 10.1016/S1352-2310(02)00322-9spa
dcterms.bibliographicCitationHuertas, M.E., Acevedo-Barrios, R.L., Rodríguez, M., Gaviria, J., Arana, R., Arciniegas, C. Identification and Quantification of Bioaerosols in a Tropical Coastal Region: Cartagena de Indias, Colombia (2018) Aerosol Science and Engineering, 2 (4), pp. 206-215. Cited 2 times. https://www.springer.com/journal/41810 doi: 10.1007/s41810-018-0037-1spa
dcterms.bibliographicCitationHumbal, C., Gautam, S., Trivedi, U. A review on recent progress in observations, and health effects of bioaerosols (2018) Environment International, 118, pp. 189-193. Cited 111 times. www.elsevier.com/locate/envint doi: 10.1016/j.envint.2018.05.053spa
dcterms.bibliographicCitationHurtado, L., Rodríguez, G., López, J., Castillo, J.E., Molina, L., Zavala, M., Quintana, P.J.E. Characterization of atmospheric bioaerosols at 9 sites in Tijuana, Mexico (2014) Atmospheric Environment, 96, pp. 430-436. Cited 38 times. www.elsevier.com/locate/atmosenv doi: 10.1016/j.atmosenv.2014.07.018spa
dcterms.bibliographicCitationQi, J., Zhong, X., Shao, Q., Gao, D., Wu, L., Huang, L., Ye, Y. Microbial activity levels in atmospheric bioaerosols in Qingdao (Open Access) (2015) Aerobiologia, 31 (3), pp. 353-365. Cited 21 times. www.wkap.nl/journalhome.htm/0393-5965 doi: 10.1007/s10453-015-9369-3spa
dcterms.bibliographicCitationJo, W.-K., Seo, Y.-J. Indoor and outdoor bioaerosol levels at recreation facilities, elementary schools, and homes (2005) Chemosphere, 61 (11), pp. 1570-1579. Cited 139 times. www.elsevier.com/locate/chemosphere doi: 10.1016/j.chemosphere.2005.04.103spa
dcterms.bibliographicCitationJones, A.M., Harrison, R.M. The effects of meteorological factors on atmospheric bioaerosol concentrations - A review (Open Access) (2004) Science of the Total Environment, 326 (1-3), pp. 151-180. Cited 655 times. doi: 10.1016/j.scitotenv.2003.11.021spa
dcterms.bibliographicCitationKim, K.-H., Kabir, E., Jahan, S.A. Airborne bioaerosols and their impact on human health (2018) Journal of Environmental Sciences (China), 67, pp. 23-35. Cited 231 times. http://www.journals.elsevier.com/journal-of-environmental-sciences/ doi: 10.1016/j.jes.2017.08.027spa
dcterms.bibliographicCitationKoneman, E. (2008) Microbiological diagnosis: Text and color atlas. Cited 4 times. Editorial Médica Panamericana, Buenos Aires, Argentinaspa
dcterms.bibliographicCitationKummer, V., Thiel, W.R. Bioaerosols - Sources and control measures (2008) International Journal of Hygiene and Environmental Health, 211 (3-4), pp. 299-307. Cited 48 times. www.urbanfischer.de/journals/intjhyg doi: 10.1016/j.ijheh.2007.06.006spa
dcterms.bibliographicCitationLee, S.C., Chang, M. Indoor and outdoor air quality investigation at schools in Hong Kong (Open Access) (2000) Chemosphere, 41 (1-2), pp. 109-113. Cited 290 times. doi: 10.1016/S0045-6535(99)00396-3spa
dcterms.bibliographicCitationLi, M., Qi, J., Zhang, H., Huang, S., Li, L., Gao, D. Concentration and size distribution of bioaerosols in an outdoor environment in the Qingdao coastal region (2011) Science of the Total Environment, 409 (19), pp. 3812-3819. Cited 105 times. doi: 10.1016/j.scitotenv.2011.06.001spa
dcterms.bibliographicCitationLiu, T., Antony Chen, L.-W., Zhang, M., Watson, J.G., Chow, J.C., Cao, J., Chen, H., (...), Xiao, W. Bioaerosol concentrations and size distributions during the autumn and winter seasons in an industrial city of central China (2019) Aerosol and Air Quality Research, 19 (5), pp. 1095-1104. Cited 21 times. http://www.aaqr.org/article/download?articleId=6890&path=/files/article/6890/13_AAQR-18-11-OA-0422_1095-1104.pdf doi: 10.4209/aaqr.2018.11.0422spa
dcterms.bibliographicCitationMadhwal, S., Prabhu, V., Sundriyal, S., Shridhar, V. Distribution, characterization and health risk assessment of size fractionated bioaerosols at an open landfill site in Dehradun, India (2020) Atmospheric Pollution Research, 11 (1), pp. 156-169. Cited 41 times. http://www.atmospolres.com/accesstext.html doi: 10.1016/j.apr.2019.10.002spa
dcterms.bibliographicCitationMedina, J., de La Hoz, S. (2018) Evaluación del comportamiento de bioaerosoles bacterianos en la unidad de cuidados intensivos neonatal (UCIN), de una institución de salud de alta complejidad en la ciudad de Barranquilla, Atlántico. Departamento de Civil y Ambiental. Universidad de la Costa, Barranquilla, Colombia, p. 114.spa
dcterms.bibliographicCitationMorgado, W. (2017) Evaluación de bioaerosoles fungí asociados a un relleno sanitario ubicado en el municipio de Tubara, departamento del Atlántico. Facultad de Ciencias Contables Económicas y Administrativas. Universidad de Manizales, p. 78. Manizales, Colombiaspa
dcterms.bibliographicCitationMorin-Sardin, S., Nodet, P., Coton, E., Jany, J.-L. Mucor: A Janus-faced fungal genus with human health impact and industrial applications (2017) Fungal Biology Reviews, 31 (1), pp. 12-32. Cited 45 times. http://www.elsevier.com doi: 10.1016/j.fbr.2016.11.002spa
dcterms.bibliographicCitationMousavi, M.S., Hadei, M., Majlesi, M., Hopke, P.K., Yarahmadi, M., Emam, B., Kermani, M., (...), Shahsavani, A. Investigating the effect of several factors on concentrations of bioaerosols in a well-ventilated hospital environment (2019) Environmental Monitoring and Assessment, 191 (7), art. no. 407. Cited 19 times. https://link.springer.com/journal/10661 doi: 10.1007/s10661-019-7559-0spa
dcterms.bibliographicCitationNageen, Y., Asemoloye, M.D., Põlme, S., Wang, X., Xu, S., Ramteke, P.W., Pecoraro, L. Analysis of culturable airborne fungi in outdoor environments in Tianjin, China (Open Access) (2021) BMC Microbiology, 21 (1), art. no. 134. Cited 11 times. http://www.biomedcentral.com/bmcmicrobiol/ doi: 10.1186/s12866-021-02205-2spa
dcterms.bibliographicCitationNavale, V., Vamkudoth, K.R., Ajmera, S., Dhuri, V. Aspergillus derived mycotoxins in food and the environment: Prevalence, detection, and toxicity (Open Access) (2021) Toxicology Reports, 8, pp. 1008-1030. Cited 45 times. http://www.journals.elsevier.com/toxicology-reports/ doi: 10.1016/j.toxrep.2021.04.013spa
dcterms.bibliographicCitationNazaroff, W.W. Teaching indoor environmental quality (2016) Indoor air, 26 (4), pp. 515-516. Cited 11 times. http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0668 doi: 10.1111/ina.12309spa
dcterms.bibliographicCitationNiazi, S., Hassanvand, M.S., Mahvi, A.H., Nabizadeh, R., Alimohammadi, M., Nabavi, S., Faridi, S., (...), Yunesian, M. Assessment of bioaerosol contamination (bacteria and fungi) in the largest urban wastewater treatment plant in the Middle East (2015) Environmental Science and Pollution Research, 22 (20), pp. 16014-16021. Cited 108 times. http://www.springerlink.com/content/0944-1344 doi: 10.1007/s11356-015-4793-zspa
dcterms.bibliographicCitationOliveira, M., Ribeiro, H., Delgado, J.L., Abreu, I. Aeromycological profile of indoor and outdoor environments (2009) Journal of Environmental Monitoring, 11 (7), pp. 1360-1367. Cited 13 times. doi: 10.1039/b820736dspa
dcterms.bibliographicCitationPashley, C.H., Fairs, A., Free, R.C., Wardlaw, A.J. DNA analysis of outdoor air reveals a high degree of fungal diversity, temporal variability, and genera not seen by spore morphology (2012) Fungal Biology, 116 (2), pp. 214-224. Cited 75 times. doi: 10.1016/j.funbio.2011.11.004spa
dcterms.bibliographicCitationRodriguez-Gomez, C., Ramirez-Romero, C., Cordoba, F., Raga, G.B., Salinas, E., Martinez, L., Rosas, I., (...), Ladino, L.A. Characterization of culturable airborne microorganisms in the Yucatan Peninsula (Open Access) (2020) Atmospheric Environment, 223, art. no. 117183. Cited 13 times. www.elsevier.com/locate/atmosenv doi: 10.1016/j.atmosenv.2019.117183spa
dcterms.bibliographicCitationRuíz-Fonseca, C., Rubiano-Labrador, C. Perfil de bacterias y hongos aerotransportados por la lluvia horizontal de la región del Salto del Tequendama (Colombia) (2021) Gestión y Ambiente, 24, pp. 1-15.spa
dcterms.bibliographicCitationRuiz-Gil, T., Acuña, J.J., Fujiyoshi, S., Tanaka, D., Noda, J., Maruyama, F., Jorquera, M.A. Airborne bacterial communities of outdoor environments and their associated influencing factors (2020) Environment International, 145, art. no. 106156. Cited 65 times. www.elsevier.com/locate/envint doi: 10.1016/j.envint.2020.106156spa
dcterms.bibliographicCitationRuzer, L.S., Harley, N.H. (2004) Aerosols handbook: measurement, dosimetry, and health effects. Cited 50 times. CRC Pressspa
dcterms.bibliographicCitationShelton, B.G., Kirkland, K.H., Flanders, W.D., Morris, G.K. Profiles of airborne fungi in buildings and outdoor environments in the United States (2002) Applied and Environmental Microbiology, 68 (4), pp. 1743-1753. Cited 530 times. doi: 10.1128/AEM.68.4.1743-1753.2002spa
dcterms.bibliographicCitationShin, S.-K., Kim, J., Ha, S.-M., Oh, H.-S., Chun, J., Sohn, J., Yi, H. Metagenomic insights into the bioaerosols in the indoor and outdoor environments of childcare facilities (Open Access) (2015) PLoS ONE, 10 (5), art. no. e0126960. Cited 71 times. http://www.plosone.org/article/fetchObject.action?uri=info:doi/10.1371/journal.pone.0126960&representation=PDF doi: 10.1371/journal.pone.0126960spa
dcterms.bibliographicCitationSpicer, R., Gangloff, H. Establishing site specific reference levels for fungi in outdoor air for building evaluation (Open Access) (2005) Journal of Occupational and Environmental Hygiene, 2 (5), pp. 257-266. Cited 17 times. doi: 10.1080/15459620590946401spa
dcterms.bibliographicCitationSuarez, P., Rivera, K., Barragan, R., Blanco, L., Rodríguez, G., Parra, C. (2017) Riesgo por bioaerosoles en la sala de urgencias de un hospital privado de Bogotá, p. 384. In: Valle Ud (ed) VI Congreso Colombiano, Conferencia Internacional CASAP, Cali, Colombiaspa
dcterms.bibliographicCitationTolabi, Z., Alimohammadi, M., Hassanvand, M.S., Nabizadeh, R., Soleimani, H., Zarei, A. The investigation of type and concentration of bio-aerosols in the air of surgical rooms: A case study in Shariati hospital, Karaj (Open Access) (2019) MethodsX, 6, pp. 641-650. Cited 15 times. http://www.journals.elsevier.com/methodsx/ doi: 10.1016/j.mex.2019.03.016spa
dcterms.bibliographicCitationUlloa-Delgado, G. (2016) Aspectos ecológicos del bosque seco tropical en el Caribe colombiano. Cited 2 times. In: Natural TICFP (ed) Tropenbos Internacional Colombia & Fondo Patrimonio Natural, Bogotá, Colombiaspa
dcterms.bibliographicCitationValsan, A.E., Priyamvada, H., Ravikrishna, R., Després, V.R., Biju, C.V., Sahu, L.K., Kumar, A., (...), Gunthe, S.S. Morphological characteristics of bioaerosols from contrasting locations in southern tropical India - A case study (Open Access) (2015) Atmospheric Environment, 122, pp. 321-331. Cited 23 times. www.elsevier.com/locate/atmosenv doi: 10.1016/j.atmosenv.2015.09.071spa
dcterms.bibliographicCitationVelez-Pereira, A. Modelación espacio-temporal de polen y esporas de hongos aerovagantes de Catalunya (1994–2015). Tesis de Maestría (2017) Universitat Autònoma De Barcelonazspa
dcterms.bibliographicCitationVelez-Pereira, A., Caicedo, Y. Análisis de los factores ambientales y ocupacionales en la concentración de aerobacterias en unidades de cuidado intensivo del hospital universitario Fernando Troconis, 2009 Santa Marta, Colombia (2014) Cuidarte, 5, p. 595. Cited 7 times.spa
dcterms.bibliographicCitationVelez-Pereira, A., Camargo, Y.C. (2011) Evaluacion de la concentracion de bioaerosoles fungí asociados al relleno aanitario Palangana, Santa Marta-Colombia. In: Norte Ud (ed) I Simposio Iberoamericano de Ingeniería de Residuos, Santa Marta, Colombiaspa
dcterms.bibliographicCitationVos, P., Garrity, G., Jones, D., Krieg, N.R., Ludwig, W., Rainey, F.A. (2009) Bergey’s manual of systematic bacteriology. Cited 2068 times. Springer, New Yorkspa
dcterms.bibliographicCitationWoudenberg, J.H.C., Groenewald, J.Z., Binder, M., Crous, P.W. Alternaria redefined (2013) Studies in Mycology, 75, pp. 171-212. Cited 568 times. www.studiesinmycology.org/content/75/1/171.full.pdf doi: 10.3114/sim0015spa
dcterms.bibliographicCitationYen, Y.-C., Yang, C.-Y., Wang, T.-N., Yen, P.-C., Ho, C.-K., Mena, K.D., Lee, T.-C., (...), Chen, P.-S. Household airborne endotoxin associated with asthma and allergy in elementary school-age children: a case–control study in Kaohsiung, Taiwan (2020) Environmental Science and Pollution Research, 27 (16), pp. 19502-19509. Cited 7 times. https://link.springer.com/journal/11356 doi: 10.1007/s11356-020-07899-xspa
dcterms.bibliographicCitationYu, H.C., Mui, K.W., Wong, L.T. Numerical simulation of bioaerosol particle exposure assessment in office environment from MVAC systems (Open Access) (2018) Journal of Computational Multiphase Flows, 10 (2), pp. 59-71. Cited 13 times. http://cmf.sagepub.com/ doi: 10.1177/1757482X17746919spa
dcterms.bibliographicCitationZhong, X., Qi, J., Li, H., Dong, L., Gao, D. Seasonal distribution of microbial activity in bioaerosols in the outdoor environment of the Qingdao coastal region (Open Access) (2016) Atmospheric Environment, 140, pp. 506-513. Cited 82 times. www.elsevier.com/locate/atmosenv doi: 10.1016/j.atmosenv.2016.06.034spa
datacite.rightshttp://purl.org/coar/access_right/c_abf2spa
oaire.versionhttp://purl.org/coar/version/c_b1a7d7d4d402bccespa
dc.type.driverinfo:eu-repo/semantics/articlespa
dc.type.hasversioninfo:eu-repo/semantics/draftspa
dc.identifier.doi10.1007/s41810-022-00151-8
dc.subject.keywordsBioaerosols;spa
dc.subject.keywordsAirborne Microorganisms;spa
dc.subject.keywordsAerosolspa
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessspa
dc.rights.ccAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.identifier.instnameUniversidad Tecnológica de Bolívarspa
dc.identifier.reponameRepositorio Universidad Tecnológica de Bolívarspa
dc.publisher.placeCartagena de Indiasspa
dc.subject.armarcLEMB
dc.type.spahttp://purl.org/coar/resource_type/c_6501spa
oaire.resourcetypehttp://purl.org/coar/resource_type/c_6501spa


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by-nc-nd/4.0/
http://creativecommons.org/licenses/by-nc-nd/4.0/

Universidad Tecnológica de Bolívar - 2017 Institución de Educación Superior sujeta a inspección y vigilancia por el Ministerio de Educación Nacional. Resolución No 961 del 26 de octubre de 1970 a través de la cual la Gobernación de Bolívar otorga la Personería Jurídica a la Universidad Tecnológica de Bolívar.